MGate 5435-T

Moxa MGate 5435-T

MGate 5135/5435 Series
MGate 5435-T ; 4-port Modbus RTU/ASCII/TCP-to-EtherNet/IP gateways, -40 to 75°C operating temperature
Free Ground Shipping on U.S. Orders over $99 $1,250.00 ON BACKORDER Estimated Availability: 02/25/2025

Please contact us via sales@neteon.net or 888-908-3330 for other product options.

ADD TO CART
Call Us 1-888-908-3330 for Availability or Possible Alternatives

Features and Benefits

moxa-mgate-5135-5435-series-datasheet-v1.1.pdf
  • Protocol conversion between Modbus and EtherNet/IP
  • Supports EtherNet/IP adapter
  • Supports Modbus RTU/ASCII/TCP client
  • Flexible deployment with Ethernet cascading and dual subnet
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • Easy device configuration via a web-based console
  • microSD card for configuration backup/duplication
  • Supports dual redundant DC power inputs and 1 relay output
  • -40 to 75°C wide operating temperature models available
  • Serial port with 2 kV isolation protection
  • Developed according to IEC 62443-4-2 with Secure Boot
View More
Overview Specifications Accessories

Introduction

The MGate 5135 /5435 gateways are 1- and 4-port industrialEthernet gateways, respectively for Modbus RTU/ASCII/TCP and EtherNet/IPnetwork communications. To integrate existing Modbus devices ontoan EtherNet/IP network, use the MGate 5135/5435 gateway as a Modbusclient to collect data and exchange data with the EtherNet/IP host.All models are protected by a rugged and compact metal housing, areDIN-rail mountable, and offer built-in serial isolation. The ruggeddesign is suitable for industrial applications such as factory automation,power, oil and gas, water and wastewater, and other process automationindustries.

Easy Configuration

The MGate 5135/5435 gateways are provided with a webconsole to make configuration easy without having to install an extrautility. In addition, HTTPS encryption of communication ensures highernetwork security. In most data-acquisition applications, configurationof devices with Modbus commands can be time-consuming and increasecosts. The MGate 5135/5435 gateways provide offline configurationvia a CSV file to help complete the Modbus settings quickly. The MGategateways also provide software-configurable pull high/low and terminationresistor settings for RS-485 2-wire to reduce efforts and the needto open the chassis.

Easy Troubleshooting

The MGate 5135/5435 gateways provide a variety of maintenancefunctions to reduce troubleshooting time and cost, including LED indicators,protocol diagnostics, traffic monitor, and tag view. These tools helpyou capture and check data to easily identify the root cause of issues,especially during the installation stage. The MGate gateways alsocome with status monitoring and fault protection functions. The statusmonitoring function notifies a PLC/DCS/SCADA system when a Modbusdevice gets disconnected or does not respond, in which case the processPLC/DCS gets the status of each end device and then issues alarmsto notify operators. The fault protection function executes actionspre-defined by the user when a host gets disconnected to prevent theend devices from going offline for long periods of time..